Analysis on the solute generating from PPS in transformer oil after electro-thermal aging
Author
Wang, Wei ; He, Dongxin ; Yang, Kai ; Chen, Shengke ; Yue, Caipeng
Author_Institution
Beijing Key Lab. of High Voltage & EMC, North China Electr. Power Univ., Beijing, China
fYear
2012
fDate
17-20 Sept. 2012
Firstpage
439
Lastpage
442
Abstract
The poor thermo stability and electrical properties of insulation paper used in an oil-immersed transformer would limit the performance and size of the transformer. In order to substitute insulation paper, we chose polyphenylene sulfide (PPS) as the object of study to make research on its electro-thermal aging characteristics. We tested PPS´s dielectrical, physical, chemical and mechanical properties before and after aging, and researched on its resultant solute in oil after aging. It can be concluded from infrared spectral analysis of PPS that a kind of small-molecule compound that contains C=O carbonyl generates from PPS after electro-thermal aging, and the resultant can be dissolved in petroleum ether. Combining with the mass spectrum analysis of transformer oil, we preliminarily confirm the molecular structural formula of the resultant, which is aldehyde with molecular weight of 242. Further research needs to make on the content of the solute in oil at different aging stages, with the expectation of aging diagnosis on PPS-oil insulation.
Keywords
ageing; paper; petroleum; polymer insulators; polymers; power transformer insulation; spectral analysis; thermal stability; transformer oil; PPS; aldehyde; carbonyl generation; chemical property; dielectrical property; electrical property; electrothermal aging characteristics; infrared spectral analysis; insulation paper; mass spectrum analysis; mechanical property; molecular structural formula; oil-immersed transformer; petroleum; physical property; polyphenylene sulfide; small-molecule compound; solute generation analysis; thermal stability; Absorption; Aging; Circuit faults; Oil insulation; Power transformer insulation; PPS; electrothermal aging; resultant; solute in transformer oil;
fLanguage
English