DocumentCode :
2278626
Title :
Calibration of four-terminal-pair resistor
Author :
DongXue, Dai ; Yongshun, Ruan ; Xiaochao, Wang
Author_Institution :
Nat. Inst. of Metrol., Beijing
fYear :
2008
fDate :
8-13 June 2008
Firstpage :
332
Lastpage :
333
Abstract :
Based on the standard capacitor acting as reference standard from 100 kHz to 10 MHz, the measurement principle of four-terminal-pair impedance and the open-short-load (OSL) technique are used to calibrate the frequency characteristic of four-terminal pair resistor. In order to eliminate or reduce the nonlinearity error of measurement instrument, the method can keep measurement range of instrument invariable by selecting different nominal standard capacitor at the different calibration frequency.
Keywords :
calibration; capacitors; error analysis; resistors; calibration; four-terminal-pair resistor; frequency 100 kHz to 10 MHz; frequency characteristics; measurement instrument; nonlinearity error reduction; open-short-load technique; standard capacitor; Calibration; Capacitors; Circuits; Electrical resistance measurement; Equations; Frequency measurement; Impedance measurement; Instruments; Measurement standards; Resistors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location :
Broomfield, CO
Print_ISBN :
978-1-4244-2399-6
Electronic_ISBN :
978-1-4244-2400-9
Type :
conf
DOI :
10.1109/CPEM.2008.4574788
Filename :
4574788
Link To Document :
بازگشت