• DocumentCode
    2279091
  • Title

    Low voltage AC-DC transfer standards at LNE

  • Author

    Poletaeff, A. ; Leprat, D.

  • Author_Institution
    LNE, Trappes, France
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    384
  • Lastpage
    385
  • Abstract
    This paper describes the method used to establish the traceability of LNE AC-DC transfer standards in the mV-range to the 1 V multijunction converter, which serves as the primary AC-DC standard. Main uncertainty components are listed and final uncertainty given for the different voltage levels. An independent method was developed for the calibration of thermal converters at 0.3 V and 0.2 V. The agreement between this method and the step-down is within the standard uncertainty.
  • Keywords
    electric current measurement; measurement standards; measurement uncertainty; low voltage AC-DC transfer standards; multijunction converter; standard uncertainty; thermal converters calibration; uncertainty; Analog-digital conversion; Calibration; Frequency conversion; Frequency domain analysis; Frequency response; Low voltage; Measurement standards; Resistors; Standards development; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574814
  • Filename
    4574814