• DocumentCode
    2279670
  • Title

    On the effect of space charges on breakdown strength by using two different injection methods

  • Author

    Qiu, X.Q. ; Chalmers, I.D.

  • Author_Institution
    Strathclyde Univ., Glasgow, UK
  • fYear
    1996
  • fDate
    23-26 Sep 1996
  • Firstpage
    180
  • Lastpage
    183
  • Abstract
    The paper reports two different space charge injection methods and their effect on breakdown strength. Space charges were injected into a point-plane gap either using a corona pin arrangement external to the gap or by applying a dc voltage to the point electrode. It has been found that the two different space charges injection methods have the same effect on minimum impulse breakdown levels in both electron-attaching and non-attaching gases. The experimental evidence indicates that the initiatory electrons resulting from detachment have a great influence on the breakdown strength
  • Keywords
    space charge; DC voltage; breakdown strength; corona pin; electron detachment; electron-attaching gas; impulse breakdown; nonattaching gas; point electrode; point-plane gap; space charge injection;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
  • Conference_Location
    Bath
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-670-9
  • Type

    conf

  • DOI
    10.1049/cp:19961017
  • Filename
    607377