    Winding position in power transformers to reduce copper losses: non-sinusoidal currents

  • Author

    Cougo, Bernardo ; Meynard, Thierry ; Forest, François ; Labouré, Eric

  • Author_Institution
    LAPLACE, Univ. Toulouse, Toulouse, France
  • fYear
    2009
  • fDate
    20-24 Sept. 2009
  • Firstpage
    1010
  • Lastpage
    1016
  • Abstract
    The orientation used to wind a transformer is important in power transformers carrying high-frequency currents. Analysis of copper losses due to skin and proximity effects is performed in order to choose the best configuration of the turns inside the winding area when conductors are carrying non-sinusoidal current. Initially results are a direct application of Dowell´s formula for the fundamental component and the harmonics of the current flowing through the winding. Later, FEA simulations confirm the relationship between current frequency, insulation thickness, winding window width and winding position.
  • Keywords
    finite element analysis; power transformers; transformer windings; FEA simulations; copper losses reduction; high-frequency currents; insulation thickness; nonsinusoidal currents; power transformers; winding position; winding window width; Power transformer losses; Resistance; Transformer windings;