DocumentCode
2279965
Title
Calibration methods for electrostatic discharge generators
Author
Borsero, M. ; Sardi, A. ; Vizio, G.
Author_Institution
Ist. Naz. di Ricerca Metrologica, Torino
fYear
2008
fDate
8-13 June 2008
Firstpage
504
Lastpage
505
Abstract
This paper describes a calibration set-up for electrostatic discharge (ESD) generators used in electromagnetic compatibility (EMC) immunity tests. A coaxial shunt and a voltage divider are used for current and voltage measurements respectively. The presented measuring systems are traceable to the national standards.
Keywords
calibration; electric current measurement; electromagnetic compatibility; electrostatic discharge; immunity testing; measurement standards; measurement systems; voltage dividers; voltage measurement; EMC immunity test; ESD; calibration method; coaxial shunt; current measurement; electromagnetic compatibility; electrostatic discharge generator; measurement system; national standards; voltage divider; voltage measurement; Calibration; Circuit testing; Coaxial components; Current measurement; Electromagnetic compatibility; Electrostatic discharge; Immunity testing; Oscilloscopes; Probes; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location
Broomfield, CO
Print_ISBN
978-1-4244-2399-6
Electronic_ISBN
978-1-4244-2400-9
Type
conf
DOI
10.1109/CPEM.2008.4574874