DocumentCode
2280127
Title
The Methane Inductive Long-Range Inspecting System Based on CAN Communication
Author
Jiang Jian-ming
Author_Institution
Jiangsu Polytech. Univ., Changzhou, China
Volume
3
fYear
2010
fDate
13-14 March 2010
Firstpage
908
Lastpage
911
Abstract
Based on the DCS system of methane sensors, the system´s communication net was changed to CAN net. It is advantageous for control center to keep fluent communication with far excavate coal spot; it enhances the safety factor and solves the problem of telecommunication. The catalytic burning technique to inspect the concentration of methane is introduced. It is also illuminated how to use MCU and SJA1000CAN controller to construct the communication node of CAN.
Keywords
computerised monitoring; controller area networks; gas sensors; inspection; CAN communication; DCS system; MCU controller; SJA1000CAN controller; catalytic burning technique; methane concentration inspection; methane inductive long-range inspecting system; methane sensors; Automation; Bridge circuits; Communication system control; Distributed control; Gas detectors; Mechatronics; Safety; Telecommunication control; Temperature sensors; Voltage; CAN; communication; methane;
fLanguage
English
Publisher
ieee
Conference_Titel
Measuring Technology and Mechatronics Automation (ICMTMA), 2010 International Conference on
Conference_Location
Changsha City
Print_ISBN
978-1-4244-5001-5
Electronic_ISBN
978-1-4244-5739-7
Type
conf
DOI
10.1109/ICMTMA.2010.185
Filename
5458730
Link To Document