DocumentCode
2281097
Title
Optimizing the series connection of thermal converters for AC current step-up
Author
Lind, K. ; Espedalen, J.H.
Author_Institution
Justervesenet, Nat. Stand. Dept., Kjeller, Norway
fYear
2002
fDate
16-21 June 2002
Firstpage
28
Lastpage
29
Abstract
When comparing AC-DC current differences of thermal converters connected in series, capacitive leakage currents from the interconnecting point to the surroundings, and the heater to thermocouple capacitance can become significant, particularly at high frequencies. A method of optimising the series connection, to reduce the leakage currents to less than 5/spl times/10/sup -6/ relative to the measured current, has been modelled and tested experimentally.
Keywords
capacitance; circuit optimisation; circuit simulation; convertors; electric current measurement; heating elements; leakage currents; thermocouples; AC current step-up thermal converters; computer aided circuit simulation; converter AC-DC current differences; current measurement; heater/thermocouple capacitance; high frequency capacitance effects; interconnecting point capacitive leakage currents; leakage current reduction; series connected thermal converter optimization; Analog-digital conversion; Capacitance; Circuits; Frequency; Inductance; Leakage current; Resistance heating; Thermal resistance; Voltage; Voltmeters;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location
Ottawa, Ontario, Canada
Print_ISBN
0-7803-7242-5
Type
conf
DOI
10.1109/CPEM.2002.1034703
Filename
1034703
Link To Document