• DocumentCode
    2281351
  • Title

    Intercomparison measurements of direct voltage from 10 kV to 200 kV between NRC, Canada and JEMIC, Japan

  • Author

    McComb, T.R. ; So, E. ; Bennett, D. ; Shimizu, K. ; Shishido, K. ; Miyakoda, M. ; Hirayama, H.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    62
  • Lastpage
    63
  • Abstract
    Two 100 kV JEMIC dividers were used as travelling standards in comparison tests against standard dividers maintained at JEMIC and at NRC. The dividers could be used independently or combined to provide a travelling standard rated at 200 kV. The voltage measured by each system is taken as the product of the ratio of that system and the reading on the corresponding multimeter. The difference between the same voltage measured on both systems simultaneously was always less than /spl plusmn/40 /spl mu/V/V.
  • Keywords
    high-voltage techniques; measurement standards; voltage dividers; voltage measurement; 10 to 200 kV; JEMIC divider; direct voltage; intercomparison measurement; multimeter; travelling standard; Circuit testing; Councils; IEC standards; Impedance; Inspection; Laboratories; Low voltage; Measurement standards; Resistors; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034720
  • Filename
    1034720