DocumentCode
2281351
Title
Intercomparison measurements of direct voltage from 10 kV to 200 kV between NRC, Canada and JEMIC, Japan
Author
McComb, T.R. ; So, E. ; Bennett, D. ; Shimizu, K. ; Shishido, K. ; Miyakoda, M. ; Hirayama, H.
Author_Institution
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
fYear
2002
fDate
16-21 June 2002
Firstpage
62
Lastpage
63
Abstract
Two 100 kV JEMIC dividers were used as travelling standards in comparison tests against standard dividers maintained at JEMIC and at NRC. The dividers could be used independently or combined to provide a travelling standard rated at 200 kV. The voltage measured by each system is taken as the product of the ratio of that system and the reading on the corresponding multimeter. The difference between the same voltage measured on both systems simultaneously was always less than /spl plusmn/40 /spl mu/V/V.
Keywords
high-voltage techniques; measurement standards; voltage dividers; voltage measurement; 10 to 200 kV; JEMIC divider; direct voltage; intercomparison measurement; multimeter; travelling standard; Circuit testing; Councils; IEC standards; Impedance; Inspection; Laboratories; Low voltage; Measurement standards; Resistors; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location
Ottawa, Ontario, Canada
Print_ISBN
0-7803-7242-5
Type
conf
DOI
10.1109/CPEM.2002.1034720
Filename
1034720
Link To Document