DocumentCode :
2281351
Title :
Intercomparison measurements of direct voltage from 10 kV to 200 kV between NRC, Canada and JEMIC, Japan
Author :
McComb, T.R. ; So, E. ; Bennett, D. ; Shimizu, K. ; Shishido, K. ; Miyakoda, M. ; Hirayama, H.
Author_Institution :
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
fYear :
2002
fDate :
16-21 June 2002
Firstpage :
62
Lastpage :
63
Abstract :
Two 100 kV JEMIC dividers were used as travelling standards in comparison tests against standard dividers maintained at JEMIC and at NRC. The dividers could be used independently or combined to provide a travelling standard rated at 200 kV. The voltage measured by each system is taken as the product of the ratio of that system and the reading on the corresponding multimeter. The difference between the same voltage measured on both systems simultaneously was always less than /spl plusmn/40 /spl mu/V/V.
Keywords :
high-voltage techniques; measurement standards; voltage dividers; voltage measurement; 10 to 200 kV; JEMIC divider; direct voltage; intercomparison measurement; multimeter; travelling standard; Circuit testing; Councils; IEC standards; Impedance; Inspection; Laboratories; Low voltage; Measurement standards; Resistors; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
Type :
conf
DOI :
10.1109/CPEM.2002.1034720
Filename :
1034720
Link To Document :