DocumentCode :
2281368
Title :
Observations of X-ray emission from a plasma focus device
Author :
Han, Myungjin ; Luo, C.M. ; Yang, T.C. ; yang, Bo ; Lee, S.J. ; Qiu, A.C.
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear :
1995
fDate :
5-8 June 1995
Firstpage :
172
Abstract :
Summary form only given, as follows. This paper describes a pulsed X-ray source that has been developed and investigated. Hydrogen is injected into the DPF-250 device with pressure (4/spl sim/6) Torr in the discharge chamber. The X-ray photo energy spectrum was measured by LIF thermoluminescence dose elements (TLDS) matched different filters of several materials. Six filters were selected and their thick are: beryllium-100, 500, aluminum-27.4, copper-10, 49, 20.33 and 200 /spl mu/m. Therefore, the X-ray energy spectra we have measured are about (3/spl sim/60) keV and totalling 70% of the total spectral emission at hu<25 keV. The X-ray yield is deduced from the digital recorder of a bolometer through an beryllium foil transmission filter (50 /spl mu/m thick). At the same time, the analogue signal output from the bolometer was recorded on an oscillograph. We have obtained the yield as (50/spl sim/90) J/shot into 4/spl pi/, the corresponding photo energy to be higher than 2.5 keV, when the stored energy was 40 kJ. The time dependent X-ray intensity from DPF was recorded with a silicon PIN detector and a Tektronix 7844 oscilloscope. Two peaks of X-ray output was observed. The duration time of X-ray is about 200 ns. A pinhole image was acquired of the DPF discharge. At a 90 degree direction with respect to the electrode axis is placed a X-ray pinhole camera with pinhole diameter 0.3 mm. The pictures show two strong exposed contours of the target of the anode and the focus.
Keywords :
X-ray emission spectra; X-ray production; X-ray spectra; bolometers; fluorescence; plasma diagnostics; plasma focus; radiometry; thermoluminescence; thermoluminescent dosimeters; 3 to 60 keV; 4 to 6 torr; 40 kJ; DPF-250 device; LIF thermoluminescence dose elements; Tektronix 7844 oscilloscope; X-ray emission; X-ray energy spectra; X-ray photo energy spectrum; bolometer; digital recorder; discharge chamber; filters; foil transmission filter; plasma focus device; pulsed X-ray source; time dependent X-ray intensity; Bolometers; Energy measurement; Filters; Focusing; Hydrogen; Plasma devices; Plasma measurements; Plasma sources; Plasma x-ray sources; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 1995. IEEE Conference Record - Abstracts., 1995 IEEE International Conference on
Conference_Location :
Madison, WI, USA
ISSN :
0730-9244
Print_ISBN :
0-7803-2669-5
Type :
conf
DOI :
10.1109/PLASMA.1995.531646
Filename :
531646
Link To Document :
بازگشت