• DocumentCode
    2281414
  • Title

    Calibration of the thd functions of electrical standards

  • Author

    Arseneau, R. ; Frigault, M. ; Zelle, J.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada-Ottawa, Ottawa, ON
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    674
  • Lastpage
    675
  • Abstract
    The paper describes a test procedure, the test waveforms, and the reference equipment used to calibrate the voltage and current total harmonic distortion (THD) measuring functions of multi-function electrical standards. It also shows that it is possible to establish traceability to the SI units for the THD measurements by measuring the voltage and power of the test waveforms with voltmeters and wattmeters that are traceable to SI. Results of recent calibrations are discussed.
  • Keywords
    calibration; harmonic distortion; measurement standards; power measurement; units (measurement); voltage measurement; voltmeters; wattmeters; SI units; THD measurement; calibration; multifunction electrical standards; power measurement; total harmonic distortion function; voltage measurement; voltmeters; wattmeters; Calibration; Current measurement; Distortion measurement; Electric variables measurement; Measurement standards; Power measurement; Testing; Total harmonic distortion; Voltage measurement; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574959
  • Filename
    4574959