• DocumentCode
    2281487
  • Title

    Attenuation measurement system in frequency range of 10-100 MHz

  • Author

    Widarta, A. ; Kawakami, Tomoya

  • Author_Institution
    AIST, Nat. Metrol. Inst. of Japan (NMIJ), Tsukuba, Japan
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    80
  • Lastpage
    81
  • Abstract
    An attenuation measurement system, which employs a traceable inductive voltage divider (IVD) at 1 kHz as a reference standard and the dual channel intermediate frequency (IF) substitution method, is developed for an attenuation standard in the frequency range of 10-100 MHz. The basic properties of the system were experimentally investigated at a frequency of 60 MHz.
  • Keywords
    VHF radio propagation; attenuation measurement; measurement standards; measurement systems; voltage dividers; 1 kHz; 10 to 100 MHz; 60 MHz; attenuation measurement system; attenuation standard; dual channel intermediate frequency substitution method; frequency range; traceable inductive voltage divider reference standard; Assembly; Attenuation measurement; Frequency measurement; Light emitting diodes; Measurement standards; Phase detection; Phase shifters; Radio frequency; Standards development; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034729
  • Filename
    1034729