DocumentCode :
2282281
Title :
A new architecture for high-accuracy admittance measuring systems
Author :
Cabiati, F. ; D´Elia, Vincenzo
Author_Institution :
Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
fYear :
2002
fDate :
16-21 June 2002
Firstpage :
178
Lastpage :
179
Abstract :
The architecture of traditional coaxial systems for highly accurate admittance comparison has been redesigned taking into account the features of active-compensated multi-coaxial connection structures previously developed and investigated. When applied to the conventional two-port transformer bridge, the new approach makes the parasitic cable effects negligible, and allows comparison of four-port standards even in parallel connection.
Keywords :
bridge instruments; electric admittance measurement; measurement standards; active compensation; admittance measuring system; coaxial system architecture; four-port standard; multi-coaxial connection structure; parallel connection; parasitic cable effects; two-port transformer bridge; Admittance measurement; Bridge circuits; Coaxial cables; Coaxial components; Conductors; Detectors; Joining processes; Measurement standards; Power cables; Voltage control;