• DocumentCode
    2282368
  • Title

    Optimization of the precise inductive voltage divider windings

  • Author

    Semenov, Yu.P. ; Horsky, J.

  • Author_Institution
    D.I. Mendeleyev Inst. for Metrol., St. Petersburg, Russia
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    192
  • Lastpage
    193
  • Abstract
    Ratio errors of inductive voltage dividers (IVDs) can be reduced by using trifilar ropes for the multifilar winding fabrication. Unevenness of distributed parameters of such a multifilar winding does not exceed 10%. Positioning the largest members of mutual capacitances matrix nearby of its main diagonal provides tenfold reduction of an IVD ratio error. The model of inner capacitive load distribution is verified by direct measurements of the rope currents by means of a current comparator.
  • Keywords
    voltage dividers; windings; current comparator; design optimization; distributed parameters; inductive voltage divider winding; inner capacitive load distribution; multifilar winding fabrication; mutual capacitance matrix; ratio error; rope current; trifilar rope; Capacitance measurement; Current distribution; Current measurement; Fabrication; Inductance; Optimization methods; Predictive models; Scattering; Voltage; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034785
  • Filename
    1034785