DocumentCode
2283092
Title
Comparative tests of impulse strength of PE and XLPE insulation
Author
Rakowska, A. ; Hajdrowski, K.
Author_Institution
Poznan Univ. of Technol., Poland
fYear
1996
fDate
23-26 Sep 1996
Firstpage
263
Lastpage
266
Abstract
In order to decrease losses in insulation the construction changes in cables are designed to introduce insulation materials boasting a decreased dielectric losses coefficient. For this reason PE and XLPE insulation is used in numerous applications, with users taking advantage of its good operating parameters and environmental protection. Insulation of constant voltage appliances is highly polarised and is also subjected to overvoltage. This can adversely affect the reliability of the line. That is why the present comparative tests of the influence of time and polarisation tension upon PE and XLPE impulse strength have been conducted
Keywords
electric strength; PE insulation; XLPE insulation; cable line; dielectric loss; impulse strength; overvoltage; polarisation tension; reliability; testing;
fLanguage
English
Publisher
iet
Conference_Titel
Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
Conference_Location
Bath
ISSN
0537-9989
Print_ISBN
0-85296-670-9
Type
conf
DOI
10.1049/cp:19961037