DocumentCode :
2283724
Title :
An inductive voltage calibration system based on bootstrapping method
Author :
Gulmez, Y. ; Gulmez, G. ; Turhan, E. ; Ozkan, T.
Author_Institution :
TUBITAK Ulusal Metroloji Enstitusu, Kocaeli, Turkey
fYear :
2002
fDate :
16-21 June 2002
Firstpage :
350
Lastpage :
351
Abstract :
The need of calibrated inductive voltage dividers (IVD) with the smallest possible uncertainties was appeared for determination, maintenance and dissemination of the ohm and the farad in audio frequencies. In this paper an IVD calibration system that is based on bootstrapping method is described and the preliminary results and improvement efforts are mentioned. The relative uncertainty of the system from the preliminary results is 2.10/sup -8/ for the inphase component, 5.10/sup -8/ for the quadrate component at 1 kHz.
Keywords :
bootstrap circuits; calibration; measurement uncertainty; units (measurement); voltage dividers; 1 kHz; audio frequency; bootstrapping method; calibration system; farad unit; inductive voltage divider; measurement uncertainty; ohm unit; Bridge circuits; Calibration; Capacitance; Copper; Magnetic cores; Permeability; Transformer cores; Uncertainty; Voltage; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
Type :
conf
DOI :
10.1109/CPEM.2002.1034866
Filename :
1034866
Link To Document :
بازگشت