• DocumentCode
    2283783
  • Title

    A method to determine the low frequency behavior of thermal converters

  • Author

    Rydler, K.-E. ; Tarasso, V.

  • Author_Institution
    SP Swedish Nat. Testing & Res. Inst., Boras, Sweden
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    358
  • Lastpage
    359
  • Abstract
    A method to determine the low frequency behaviour of thermal converters using a resistor as standard is described. The method has been used to determine the AC-DC transfer difference of multijunction thermal converters and planar multijunction thermal converters in the frequency range 10 Hz to 400 Hz. The results of a comparison agree with predicted values within /spl plusmn/0.5-10/sup -6/.
  • Keywords
    convertors; electric current measurement; frequency response; measurement standards; resistors; voltage measurement; 10 to 400 Hz; AC voltage/current measurement; AC-DC transfer difference; converter frequency range; planar multijunction thermal converters; resistor standard; thermal converter low frequency behavior; Analog-digital conversion; Current measurement; Frequency conversion; Frequency estimation; Frequency measurement; Heat transfer; Resistors; Testing; Thermal resistance; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034870
  • Filename
    1034870