DocumentCode :
2283893
Title :
DC electrical accelerated ageing tests on polyethylene insulation
Author :
Brown, M.A. ; Chen, G. ; Rogers, B.F. ; Davies, A.E. ; Rochester, C.
Author_Institution :
Dept. of Electr. Eng., Southampton Univ., UK
fYear :
1996
fDate :
23-26 Sep 1996
Firstpage :
281
Lastpage :
284
Abstract :
This paper reports on an on-going study into assessing the long term dc performance and reliability of moulded production joints used in submarine repeatered optic communication cable systems. Emphasis is being placed on using meaningful short term accelerated ageing tests, results of which can be extrapolated to service life and conditions. Electrical breakdown data from ramp and constant stress tests of production mouldings are presented along with thin film samples microtomed from various parts of mouldings. Bulk space charge measurements of aged samples are reported and their effect on failure data are discussed
Keywords :
polyethylene insulation; DC electrical accelerated ageing test; electrical breakdown; failure; microtomed thin film; moulded production joint; polyethylene insulation; reliability; service life; space charge; submarine repeatered optic communication cable system;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
Conference_Location :
Bath
ISSN :
0537-9989
Print_ISBN :
0-85296-670-9
Type :
conf
DOI :
10.1049/cp:19961041
Filename :
607400
Link To Document :
بازگشت