DocumentCode :
2284129
Title :
Influence of the Metallic Shield on the Antenna Temperature Calibration for the Microwave Radiometer
Author :
Hui, Xiao ; Jungang, Miao ; Yujie, Yang ; Yi, Peng
Author_Institution :
Beihang Univ., Beijing
fYear :
2007
fDate :
16-17 Aug. 2007
Firstpage :
648
Lastpage :
651
Abstract :
In the calibration of a microwave radiometer, the calibration load is equipped with a metallic shield. The metallic shield is found to introduce aberration to the measurements of the antenna temperature. In this work, a ray-tracing model is constructed for the aberration analysis, which is based on the radiation transfer theory taking into account both the conductivity of the metal and the temperature distribution of the shield. Calculation results indicate that the temperature aberration due to the metal shield can be up to a few tenths of Kelvin, depending on the metal, the geometry of the shield and the size of the antenna. The calculation result is also compared with the experimental data.
Keywords :
aberrations; calibration; microwave antennas; radiometers; ray tracing; temperature distribution; aberration analysis; antenna temperature calibration; calibration load; metallic shield; microwave radiometer; radiation transfer theory; ray-tracing model; temperature aberration; temperature distribution; Antenna measurements; Calibration; Conductivity; Geometry; Kelvin; Microwave antennas; Microwave radiometry; Ray tracing; Temperature dependence; Temperature distribution; Radiometer calibration; brightness temperature; radiation transfer theory;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications, 2007 International Symposium on
Conference_Location :
Hangzhou
Print_ISBN :
978-1-4244-1045-3
Electronic_ISBN :
978-1-4244-1045-3
Type :
conf
DOI :
10.1109/MAPE.2007.4393704