Title :
Type B uncertainty evaluation of IEN CSF1 primary frequency standard
Author :
Levi, F. ; Lorini, L. ; Calonico, D. ; Godone, A.
Author_Institution :
Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
Abstract :
We report the first accuracy evaluation of the new IEN Cs fountain primary frequency standard. Although preliminary, and performed in absence of a resident H-maser, all the principal effects are evaluated at few units of 10/sup -15/ level. Differential measurements and TWSTFT remote comparisons were used to supply in the absence of the H-maser.
Keywords :
atomic clocks; caesium; frequency standards; masers; measurement uncertainty; particle traps; radiation pressure; Cs; H-maser; IEN CSF1 primary frequency standard; IEN Cs fountain primary frequency standard; TWSTFT remote comparisons; differential measurements; type B uncertainty evaluation; Atomic beams; Atomic measurements; Coils; Density measurement; Frequency measurement; Laboratories; Magnetic shielding; Optical pulses; Performance evaluation; Uncertainty;
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
DOI :
10.1109/CPEM.2002.1034909