• DocumentCode
    2284571
  • Title

    Electrical rotating plant-condition monitoring

  • Author

    Smith, J.W.R.

  • Author_Institution
    BAe SEMA Ltd., UK
  • fYear
    1996
  • fDate
    23-26 Sep 1996
  • Firstpage
    387
  • Lastpage
    393
  • Abstract
    The paper considers the application of Condition Monitoring Techniques to the HV electrical insulation of large electric motors and generators. A philosophy for condition monitoring is suggested. Examples of test techniques applicable are proposed with descriptions of their applicability and method of analysis
  • Keywords
    machine insulation; HV electrical insulation; condition monitoring; electric generator; electric motor; electrical rotating plant;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
  • Conference_Location
    Bath
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-670-9
  • Type

    conf

  • DOI
    10.1049/cp:19961065
  • Filename