DocumentCode
2284571
Title
Electrical rotating plant-condition monitoring
Author
Smith, J.W.R.
Author_Institution
BAe SEMA Ltd., UK
fYear
1996
fDate
23-26 Sep 1996
Firstpage
387
Lastpage
393
Abstract
The paper considers the application of Condition Monitoring Techniques to the HV electrical insulation of large electric motors and generators. A philosophy for condition monitoring is suggested. Examples of test techniques applicable are proposed with descriptions of their applicability and method of analysis
Keywords
machine insulation; HV electrical insulation; condition monitoring; electric generator; electric motor; electrical rotating plant;
fLanguage
English
Publisher
iet
Conference_Titel
Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
Conference_Location
Bath
ISSN
0537-9989
Print_ISBN
0-85296-670-9
Type
conf
DOI
10.1049/cp:19961065
Filename
607424
Link To Document