Title :
Thrust measurement at micronewton level
Author :
Bertinetto, F. ; Bisi, M. ; Cordiale, P. ; Canuto, E. ; Rolino, A. ; Cesare, S.
Author_Institution :
Ist. di Metrologia "G. Colonnetti", Torino, Italy
Abstract :
An interferometric force balance (Nanobalance) for space micro-thruster qualification is presented. A new generation of space micro-thrusters is under development aiming at thrust resolution and accuracy below one micronewton. Nanobalance has been conceived and developed for ground calibration of thrust time profile and noise with sub-micronewton accuracy.
Keywords :
aerospace propulsion; calibration; force measurement; light interferometers; microbalances; Nanobalance; ground calibration; interferometric force balance; micronewton level; noise; space micro-thruster; thrust measurement; thrust time profile; Assembly; Damping; Degradation; Density measurement; Force measurement; Frequency conversion; Resonant frequency; Signal processing; Testing; Vacuum systems;
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
DOI :
10.1109/CPEM.2002.1034950