DocumentCode :
2285729
Title :
Transformer Core Unbalancing Issue in a Full-Bridge DC-DC Converter with Current Doubler Rectifier
Author :
Gusev, B.A. ; Meleshin, V.I. ; Ovchinnikov, D.A.
Author_Institution :
ZAO Svyaz Eng., Moscow
fYear :
2006
fDate :
12-15 Dec. 2006
Firstpage :
1
Lastpage :
6
Abstract :
Transformer core saturation in a full-bridge, phase-shift DC-DC converter with current doubler rectifier has been considered. Equations allowing to calculate maximum value of the flux density in the core have been obtained. The theoretical analysis and calculations were verified by simulation and experiments of DC-DC converter with 2500 W output power. Main causes of asymmetrical regimes have been revealed and suggested methods preventing a phenomena.
Keywords :
DC-DC power convertors; bridge circuits; multiplying circuits; rectifying circuits; transformer cores; 2500 W; asymmetrical regimes; core saturation; current doubler rectifier; flux density; full-bridge DC-DC converter; phase-shift converter; transformer core unbalancing; Circuit faults; DC-DC power converters; Equations; Inductors; Power generation; Pulse width modulation; Rectifiers; Stress; Switching converters; Transformer cores; current doubler rectifier; full-bridge DC-DC converter; transformer core; unbalancing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics, Drives and Energy Systems, 2006. PEDES '06. International Conference on
Conference_Location :
New Delhi
Print_ISBN :
0-7803-9772-X
Electronic_ISBN :
0-7803-9772-X
Type :
conf
DOI :
10.1109/PEDES.2006.344409