DocumentCode :
2286242
Title :
Simulation Study of a Shunt Active Power Filter Using Nonlinear Least Squares Harmonic Extraction Technique
Author :
Chudamani, R. ; Vasudevan, K. ; Ramalingam, C.S.
Author_Institution :
Dept. of Electr. Eng., Indian Inst. of Technol., Chennai
fYear :
2006
fDate :
12-15 Dec. 2006
Firstpage :
1
Lastpage :
5
Abstract :
In the control strategies for an active power filter, determination of harmonic components of the load current is the most important stage. In this paper the behaviour of the shunt active power filter using the ´nonlinear least squares´ estimation technique for extracting the harmonic components of the load current is studied. The performance of active power filter under steady state and dynamic load conditions are analyzed. Simulation results depict a satisfactory performance even under step load changes.
Keywords :
active filters; electric current control; least squares approximations; nonlinear estimation; power harmonic filters; control strategy; harmonic components extraction; load current; nonlinear least squares estimation technique; shunt active power filter; Active filters; Adaptive filters; Artificial neural networks; Delay; Frequency estimation; Least squares approximation; Least squares methods; Power harmonic filters; Power system harmonics; Steady-state; Active Power Filter; Nonlinear least squares;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics, Drives and Energy Systems, 2006. PEDES '06. International Conference on
Conference_Location :
New Delhi
Print_ISBN :
0-7803-9772-X
Electronic_ISBN :
0-7803-9772-X
Type :
conf
DOI :
10.1109/PEDES.2006.344228