    A New Power Quality Enhancement Method for Two-Phase Loads

  • Author

    Hojabri, H. ; Mokhtari, H.

  • Author_Institution
    Sharif Univ. of Technol., Tehran
  • fYear
    2006
  • fDate
    12-15 Dec. 2006
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper describes a new compensating system for the flicker and harmonics generated by a highly-varying load, e.g. a welding machine, connected between two phases of a three-phase system. The proposed system is an active filter with two-phase structure employed in a three-phase system. The system also employs simple and effective control strategies for de-bus regulation and current control. The proposed system is a package with less switches compared to the conventional three-phase systems. It results in no increase in switch ratings, thus giving a more economic compensator.
  • Keywords
    active filters; electric current control; power supply quality; power system control; power system harmonics; active filter; current control; de-bus regulation; harmonics compensation; power quality enhancement method; three-phase system; two-phase load; Active filters; Power generation; Power generation economics; Power harmonic filters; Power quality; Power system harmonics; Spot welding; Switches; Voltage fluctuations; Wire; active power filter; current harmonic compensation; flicker mitigation; two-phase loads;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Drives and Energy Systems, 2006. PEDES '06. International Conference on
  • Conference_Location
    New Delhi
  • Print_ISBN
    0-7803-9772-X
  • Electronic_ISBN
    0-7803-9772-X
  • Type

    conf

  • DOI
    10.1109/PEDES.2006.344241
  • Filename
    4147948