DocumentCode
2288703
Title
Mogul-D Marx generator upgrade and predicted output
Author
Stevens, Andrew ; Sinclair, M.
Author_Institution
AWE Aldermaston, Reading, UK
fYear
2005
fDate
8-8 Sept. 2005
Abstract
Mogul-D is a pulsed power flash X-ray machine forming a part of one of AWEs flash radiographic facilities. At the age of twenty-five, Mogul-D no longer has the reliability it once had. With two of its seventy ICSE capacitors broken but not removed, due to fears over its structural integrity it was decided to replace the ISCE capacitor based Marx with a Sandia style hanging Marx configured with five columns of twelve capacitors plus one column of eight capacitors. This report will show details of the method used in designing the new Marx configuration as well as transmission-line code (Bertha) predictions of the voltage output of the upgraded machine.
Keywords
X-ray apparatus; maintenance engineering; power capacitors; pulse generators; pulsed power supplies; reliability; ICSE capacitors; ISCE capacitor; Mogul-D marx generator; X-ray machine; pulsed power flash; radiographic facility; reliability; transmission-line code;
fLanguage
English
Publisher
iet
Conference_Titel
Pulsed Power symposium, 2005. The IEE (Reg. No. 2005/11070)
Conference_Location
Basingstoke, UK
ISSN
0537-9989
Print_ISBN
0-86341-558-X
Type
conf
DOI
10.1049/ic:20050046
Filename
1524503
Link To Document