DocumentCode :
2291076
Title :
A wide area differential backup protection scheme for shipboard application
Author :
Tang, J. ; McLaren, P.G.
Author_Institution :
Center for Adv. Power Syst., Florida State Univ., Tallahassee, FL, USA
fYear :
2005
fDate :
27-27 July 2005
Firstpage :
219
Lastpage :
224
Abstract :
A new wide area differential protection (WADP) system is proposed to suit the need of the shipboard application where short cables make conventional backup schemes impractical. The close proximity of all the components in a shipboard power system makes communication less of an issue than in a land-based system. With an overall view of the protected system and by use of a differential search algorithm, a minimum fault isolation area is decided. A built-in confirmation mechanism avoids unnecessary or false tripping due to protection component failure. Simulation results are shown for a small shipboard power system (SPS).
Keywords :
electrical faults; power system protection; ships; backup schemes; built-in confirmation mechanism; differential search algorithm; fault isolation; land-based system; protection component failure; shipboard application; shipboard power system; wide area differential backup protection scheme; Cables; Circuit faults; Fault location; Impedance measurement; Power system faults; Power system protection; Power system relaying; Power system reliability; Power system simulation; Protective relaying;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Ship Technologies Symposium, 2005 IEEE
Conference_Location :
Philadelphia, PA
Print_ISBN :
0-7803-9259-0
Type :
conf
DOI :
10.1109/ESTS.2005.1524678
Filename :
1524678
Link To Document :
بازگشت