DocumentCode
2291198
Title
Accurate method to measure harmonics and interharmonics in shipboard power quality analysis
Author
Kondabathini, A.K. ; Ginn, Herbert L., III ; Molen, G.M.
Author_Institution
Mississippi State Univ., MS, USA
fYear
2005
fDate
27-27 July 2005
Firstpage
255
Lastpage
260
Abstract
This paper describes a novel approach that utilizes a special property of the Hanning window to accurately detect the fundamental frequency of the data signal in the presence harmonic and interharmonic interference. After obtaining the fundamental frequency the same procedure is applied to all possible harmonics to be filtered for further analysis of the interharmonics. The proposed approach is validated using numerical tests with considerable accuracy.
Keywords
power supply quality; power system harmonics; ships; Hanning window; fundamental frequency; harmonic interference; harmonics measurement; interharmonic interference; interharmonics measurement; shipboard power quality analysis; Discrete Fourier transforms; Frequency; Harmonic analysis; Power harmonic filters; Power measurement; Power quality; Power system harmonics; Signal analysis; Signal processing; Signal processing algorithms;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Ship Technologies Symposium, 2005 IEEE
Conference_Location
Philadelphia, PA
Print_ISBN
0-7803-9259-0
Type
conf
DOI
10.1109/ESTS.2005.1524685
Filename