This paper describes a novel approach that utilizes a special property of the Hanning window to accurately detect the fundamental frequency of the data signal in the presence harmonic and interharmonic interference. After obtaining the fundamental frequency the same procedure is applied to all possible harmonics to be filtered for further analysis of the interharmonics. The proposed approach is validated using numerical tests with considerable accuracy.
Keywords :
power supply quality; power system harmonics; ships; Hanning window; fundamental frequency; harmonic interference; harmonics measurement; interharmonic interference; interharmonics measurement; shipboard power quality analysis; Discrete Fourier transforms; Frequency; Harmonic analysis; Power harmonic filters; Power measurement; Power quality; Power system harmonics; Signal analysis; Signal processing; Signal processing algorithms;