• DocumentCode
    230137
  • Title

    Measured loss evaluation of asymmetrical parameter type two-phase induction motor supplied with a three-leg voltage source inverter

  • Author

    Kongsuk, Prayad ; Promkhun, Watcharin ; Kinnares, Vijit

  • Author_Institution
    Dept. of Electr. Eng., King Mongkut´s Inst. of Technol., Ladkrabang, Thailand
  • fYear
    2014
  • fDate
    22-25 Oct. 2014
  • Firstpage
    2561
  • Lastpage
    2566
  • Abstract
    This paper presents the measured power losses of asymmetrical parameter type Two-Phase Induction Motor supplied with three-leg voltage source inverter. The comparison of the motor losses between balanced and unbalanced voltages supplied to both windings of the two-phase induction motor under variation of voltages at various inverter frequencies and various loads is given. A dSPIC microcontroller is employed to generate space vector pulse width modulation signals with switching frequency of 5 kHz for the two-phase three-leg VSI. The experimental results are shown that an unbalanced phase voltage case give lower losses than a balanced phase voltage case at the same modulation index, frequency and load. When decreasing main voltage winding from the rated value for both cases, there are minimum values of losses for each load torque value.
  • Keywords
    PWM invertors; induction motors; machine control; asymmetrical parameter type two-phase induction motor; dSPIC microcontroller; frequency 5 kHz; measured loss evaluation; space vector pulse width modulation signals; three-leg voltage source inverter; two-phase three-leg VSI; Core loss; Induction motors; Inverters; Loss measurement; Vectors; Voltage measurement; Windings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems (ICEMS), 2014 17th International Conference on
  • Conference_Location
    Hangzhou
  • Type

    conf

  • DOI
    10.1109/ICEMS.2014.7013933
  • Filename
    7013933