DocumentCode :
230246
Title :
Analysis and design of separated permanent magnet actuator for 225AF molded case circuit breaker
Author :
Hyeon-Jeong Park ; So-Hyun Kim ; Jong-Suk Ro ; Hyun-Kyo Jung
Author_Institution :
Dept. of Electr. & Comput. Eng., Seoul Nat. Univ., Seoul, South Korea
fYear :
2014
fDate :
22-25 Oct. 2014
Firstpage :
2888
Lastpage :
2891
Abstract :
The conventional motor-driven MCCB (molded-case circuit breaker) is not only large in size, but also inefficient in performance. To solve these problems, this paper suggests SPMA (separate permanent-magnet actuator), a novel magnetic actuator. In this paper, SPMA is designed for a 225AF MCCB and compared to a conventional motor-driven MCCB and to an EMFA (electro-magnetic force driving actuator)-type MCCB.
Keywords :
circuit breakers; electromagnetic forces; magnetic actuators; permanent magnet motors; 225AF molded case circuit breaker; EMFA; SPMA; electromagnetic force driving actuator type; magnetic actuator; motor-driven MCCB; separate permanent-magnet actuator; Actuators; Coils; Equations; Force; Magnetic circuits; Magnetic forces; Magnetic separation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2014 17th International Conference on
Conference_Location :
Hangzhou
Type :
conf
DOI :
10.1109/ICEMS.2014.7013990
Filename :
7013990
Link To Document :
بازگشت