Title :
Transient behavior of doubly fed induction generator during voltage recovery
Author :
Sheng Hu ; Xudong Zou ; Yong Kang
Author_Institution :
Sch. of Electr. & Electron. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
Abstract :
DFIG is very sensitive to grid voltage disturbance, grid voltage dip and recovery may cause overcurrents an overvoltages in rotor windings, which can damage the rotor side converter(RSC). The transient behavior of DFIG under voltage dip has been studied in many literatures, but the behavior of DFIG under voltage recovery after voltage dip is seldom reported, the transient behavior of DFIG during voltage recovery after balanced and unbalanced voltage dip are theoretically analyzed in this paper, in order to validate theory analysis, simulations have been carried out, the results are consistent with proposed theoretical analysis.
Keywords :
asynchronous generators; power convertors; DFIG; RSC; doubly fed induction generator; grid voltage dip; grid voltage disturbance; rotor side converter; rotor windings; theory analysis; transient behavior; unbalanced voltage dip; voltage recovery; Rotors; Stator windings; Steady-state; Transient analysis; Vectors; Voltage fluctuations;
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2014 17th International Conference on
Conference_Location :
Hangzhou
DOI :
10.1109/ICEMS.2014.7014040