DocumentCode
2308040
Title
Study on body surface infrared radiation spectrum of points of patients with hyperplasia of mammary gland
Author
Ying Jian ; Shen Xueyong ; Li Heng ; Ding Guanghong ; Chen Hongfeng ; Sun Chenping ; Hu Shengfang
Author_Institution
Coll. of Acupuncture-Moxibustion & Tuina, Shanghai Univ. of Traditional Chinese Med., Shanghai
fYear
2008
fDate
12-14 Dec. 2008
Firstpage
587
Lastpage
591
Abstract
Objective: To compare the difference of body surface infrared radiation (IR) spectrum between the point Qimen (LR14), point Danzhong (CV17) and non-acupoint control point of patients with hyperplasia of mammary gland (HMG). Methods: Sixty-eight patients with HMG were enrolled in this trail. The infrared radiation spectrum of left and right point Qimen (LR14), point Danzhong (CV17) and control point were detected by the high-sensitive PHE201 body surface infrared spectrometer, the wavelength from 1.5 m to 16 m were used. Results: There were 49 wavelengths (3.50, 4.00, 4.50~16.00 m) among 59 detected wavelengths, the IR intensity of left point Qimen (LR14) was significantly higher than that of the control point (p<0.05). There were 48 wavelengths (1.75, 3.50, 4.00, 4.50~6.50, 7.00, 7.50~16.00 m) among 59 detected wavelengths, the IR intensity of right point Qimen (LR14) was significantly higher than that of the control point (p<0.05). There were 13 wavelengths ( 6.75~8.25, 9.00, 9.25, 9.75, 13.25~13.75 m) among 59 detected wavelengths, the IR intensity of point Danzhong (CV17) was significantly lower than that of the control point (p<0.05). Conclusion: The infrared radiation intensity of point Qimen (LR14) is higher than that of the control point, while the infrared radiation intensity of point Danzhong (CV17) is lower than that of the control point, which indicates that the deficiency and excess of qi and blood of points from different.
Keywords
biological tissues; biothermics; infrared spectra; medical diagnostic computing; patient diagnosis; body surface infrared radiation spectrum difference comparison; high-sensitive PHE201 body surface infrared spectrometer; mammary gland hyperplasia patients; nonacupoint control point; point Danzhong; point Qimen; qi excess; wavelength 1.5 mum to 16 mum; Breast; Humans; Infrared detectors; Infrared heating; Infrared spectra; Mammary glands; Pathology; Radiation detectors; Spectroscopy; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
IT in Medicine and Education, 2008. ITME 2008. IEEE International Symposium on
Conference_Location
Xiamen
Print_ISBN
978-1-4244-3616-3
Electronic_ISBN
978-1-4244-2511-2
Type
conf
DOI
10.1109/ITME.2008.4743932
Filename
4743932
Link To Document