Title :
Do multi-flash solar simulators measure the wrong fill factor?
Author :
Ossenbrink, H.A. ; Zaaiman, W. ; Bishop, J.
Author_Institution :
Joint Res. Centre, Commission of the Eur. Communities, Ispra, Italy
Abstract :
This paper describes measurement errors introduced by multi-flash solar simulators as used in production control of photovoltaic modules. Depending on the adjustment of the sampling interval of the data acquisition system, changes in the fill factor of the measured I-V characteristics may occur when devices with high capacitance, such as BSF-cells, are measured. The paper describes the measurement and analysis procedure and possible solutions
Keywords :
data acquisition; measurement errors; semiconductor device testing; solar cells; BSF-cells; I-V characteristics; analysis procedure; capacitance; data acquisition; fill factor; measurement errors; multi-flash solar simulators; photovoltaic modules; production control; solar cells; testing; Capacitance measurement; Data acquisition; Delay; Measurement errors; Photovoltaic systems; Production control; Sampling methods; Solar power generation; Testing; Voltage;
Conference_Titel :
Photovoltaic Specialists Conference, 1993., Conference Record of the Twenty Third IEEE
Conference_Location :
Louisville, KY
Print_ISBN :
0-7803-1220-1
DOI :
10.1109/PVSC.1993.346953