• DocumentCode
    2311914
  • Title

    Real data microwave imaging and time reversal

  • Author

    Chatelée, Vincent ; Dubois, Anthony ; Aliferis, Iannis ; Dauvignac, Jean-Yves ; Pichot, Christian ; Yedlin, Matthew J.

  • Author_Institution
    Univ. de Nice, Nice
  • fYear
    2007
  • fDate
    9-15 June 2007
  • Firstpage
    1793
  • Lastpage
    1796
  • Abstract
    The development of SIMIS (Synthetic Impulse Microwave Imaging System), a microwave array of eight ultra-wideband Vivaldi-type ETSA antennas, employed to image unknown targets situated in an anechoic chamber, is presented. Real scattering data, collected via an RF multiplexer interfaced to a vector network analyzer, is imaged using the Time Reversal Method. The imaging algorithm is applied to the scattered field from a dielectric cylinder. In addition, real data is presented for the same dielectric cylinder, located behind a vertical wall.
  • Keywords
    anechoic chambers (electromagnetic); dielectric bodies; electromagnetic wave scattering; microwave antenna arrays; microwave imaging; multiplexing equipment; network analysers; slot antenna arrays; ultra wideband antennas; RF multiplexer; SIMIS; anechoic chamber; dielectric cylinder; exponentially tapered slot antenna; microwave array; real data microwave imaging; scattered field; synthetic impulse microwave imaging system; time reversal method; ultra-wideband Vivaldi-type ETSA antennas; vector network analyzer; Anechoic chambers; Dielectrics; Image analysis; Microwave antenna arrays; Microwave imaging; Multiplexing; Radio frequency; Scattering; Ultra wideband antennas; Ultra wideband technology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation Society International Symposium, 2007 IEEE
  • Conference_Location
    Honolulu, HI
  • Print_ISBN
    978-1-4244-0877-1
  • Electronic_ISBN
    978-1-4244-0878-8
  • Type

    conf

  • DOI
    10.1109/APS.2007.4395864
  • Filename
    4395864