DocumentCode :
2317423
Title :
Effect of the stray magnetic field on the gyrotrons for ITER
Author :
Kajiwara, Ken ; Oda, Yasuhisa ; Kasugai, Atsushi ; Takahashi, Koji ; Kobayashi, Noriyuki ; Sakamoto, Keishi ; Caroline, Darbos ; Henderson, Mark
Author_Institution :
Japan Atomic Energy Agency, Naka, Japan
fYear :
2009
fDate :
21-25 Sept. 2009
Firstpage :
1
Lastpage :
2
Abstract :
The effect of the stray magnetic field to the gyrotron collector is analyzed. The analysis includes the stray magnetic field from the adjacent gyrotrons and tokamak. In order to avoid the effect of the stray magnetic field from the adjacent gyrotrons, the minimum distance between the gyrotrons is estimated as 4 m. The effect of the stray magnetic field from tokamak on gyrotron collector (~100 m from tokamak) is negligible compared to the adjacent gyrotron with 4 m distance.