    The lifetime of the stator winding insulation is reduced when operated with PWM inverters, since insulation degradation is accelerated due to increased thermal and electrical stresses on the motor. This paper focuses on a new approach for monitoring the condition of the stator insulation for failure-prone inverter-fed machines. The main concept of the proposed technique is to apply a variable frequency AC test voltage to the stator insulation using the inverter, to perform standard off-line insulation tests whenever the motor is not operating. This allows the stator insulation to be tested more frequently compared to off-line tests performed once every 3-6 yrs. during periodic maintenance. A method for testing the insulation with minimal modifications to the inverter circuit is proposed and verified experimentally. The results show that the proposed technique provides a simple low cost solution for detecting stator insulation degradation at an early stage for reliable operation of inverterfed machine systems, since the insulation condition can be monitored frequently. This not only helps prevent forced outages and safety risks due to insulation breakdown, but also helps perform maintenance in an efficient manner since individual motor maintenance can be prioritized and scheduled based on its present condition.
  • Keywords
    AC machines; PWM invertors; condition monitoring; stators; AC machines; AC test voltage; PWM inverters; condition monitoring; failure prone inverter fed machines; insulation breakdown; insulation condition; insulation quality assessment; inverter embedded stator winding; AC machines; Circuit testing; Condition monitoring; Dielectrics and electrical insulation; Insulation testing; Maintenance; Pulse width modulation inverters; Quality assessment; Stator windings; Thermal stresses; AC Electric Machines; Capacitance Test; Condition Monitoring; Diagnostics; Dissipation Factor; Insulation Resistance; Inverters; Predictive Maintenance; Stator Insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-1621-9
  • Electronic_ISBN
    978-1-4244-1622-6
  • Type

    conf

  • DOI
    10.1109/CMD.2008.4580250
  • Filename
    4580250