DocumentCode :
2317753
Title :
Off-Line PD diagnosis for stator winding of Rotating Machines using UWB sensors
Author :
Lwin, Kyaw-Soe ; Lim, Kwang-Jin ; Shin, Dong-Hoon ; Park, Noh-Joon ; Park, Dae-Hee ; Bok Cho, Kyu ; Kim, Hee-Dong
Author_Institution :
Wonkwang Univ., Iksan
fYear :
2008
fDate :
21-24 April 2008
Firstpage :
155
Lastpage :
158
Abstract :
We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with UWB sensor. In this study, we design new type of compact low frequency UWB sensor based on micro-strip technology and make many experiments of offline and dismantled testing compare with the existing HFCT on stator winding of HV generator in the laboratory. We mentioned detail design of new compact UWB sensor design and time domain and frequency domain results of partial discharge in stator winding of 6.6kV rotating machine by offline testing in laboratory.
Keywords :
electric machines; electric sensing devices; electromagnetic waves; partial discharges; stators; UWB sensors; electromagnetic wave; microstrip technology; partial discharge diagnosis; rotating machines; stator winding; voltage 6.6 kV; Frequency; Laboratories; Microstrip antennas; Partial discharges; Power transformer insulation; Rotating machines; Stator windings; Testing; Thermal stresses; Ultra wideband antennas; 6.6kV rotating machine; HFCT; Off-line PD diagnosis; UWB sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-1621-9
Electronic_ISBN :
978-1-4244-1622-6
Type :
conf
DOI :
10.1109/CMD.2008.4580252
Filename :
4580252
Link To Document :
بازگشت