Online monitoring of dispersion functions and transfer matrices at the SLC
Author :
Emma, P. ; Fieguth, H. ; Lohse, T. ; Burchat, P.R. ; Panvini, R.S.
Author_Institution :
Linear Accel. Center, Stanford Univ., CA, USA
fYear :
1989
fDate :
20-23 Mar 1989
Firstpage :
1599
Abstract :
The symmetries of the chromatic correction sections in the SLC (Stanford Linear Collider) Final Focus System allow a high-resolution determination of the pulse-to-pulse energy fluctuations by exploiting the information from beam position monitors (BPMs) in regions of large dispersion. By correlating this signal with other BPMs, it is possible to infer the dispersion function as well as spatial components of transfer matrices anywhere in the arcs and Final Focus System without interrupting normal machine operation. Results from data recorded during periods of stable operation and when the linac energy was intentionally varied are presented
Keywords :
beam handling equipment; beam handling techniques; focusing; linear accelerators; Final Focus System; SLC; beam position monitors; chromatic correction sections; dispersion functions; high-resolution; pulse-to-pulse energy fluctuations; stable operation; transfer matrices; Carbon capture and storage; Contracts; Dispersion; Energy measurement; Extraterrestrial measurements; Fluctuations; Linear particle accelerator; Monitoring; Telescopes; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
Conference_Location :
Chicago, IL
Type :
conf
DOI :
10.1109/PAC.1989.72865
Filename :
72865
Link To Document :
بازگشت