• DocumentCode
    2318994
  • Title

    Verification of a model-based diagnosis system for on-line detection of the moisture content of power transformer insulations using finite element calculations

  • Author

    Hribernik, Wolfgang ; Kubicek, Bernhard ; Pascoli, Gert ; Fröhlich, Klaus

  • Author_Institution
    Arsenal Res. Monitoring, Energy & Drive Technol., Vienna
  • fYear
    2008
  • fDate
    21-24 April 2008
  • Firstpage
    475
  • Lastpage
    478
  • Abstract
    It is a well known fact that the moisture content of a power transformer insulation system is a key parameter for the estimation of its aging condition and operation reliability. Therefore, detection of the moisture content is a very essential task within power transformer diagnostics. While conventional methods for estimation of the water content of the insulation system require a transformer shutdown of several hours, the proposed method calculates the profiles of water concentration in the cellulosic part of the insulation system, as well as the concentration of water in transformer oil from operational parameters. An one-dimensional model for the moisture diffusion in paper estimates the temperature dependent moisture distributions in the paper. It includes temperature dependent diffusion coefficients and acts as a non-linear control loop for the water concentration in transformer oil. Beside experimental work, two-dimensional finite element (FE) calculations of the temperature dependent water concentration distribution in the transformer insulation system have been performed for model verification. The calculations are based on an opensource Whitney-Element solver. The computed results show the validity of the diffusion model and give important guidelines for the required complexity of thermal models.
  • Keywords
    ageing; finite element analysis; moisture; parameter estimation; power transformer insulation; reliability; transformer oil; aging condition; finite element calculations; model verification; model-based diagnosis system; moisture content; moisture diffusion; nonlinear control loop; on-line detection; opensource Whitney- Element solver; operation reliability; parameter estimation; power transformer insulations; temperature dependent diffusion coefficients; transformer shutdown; water concentration; water content estimation; Finite element methods; Moisture; Oil insulation; Parameter estimation; Power system modeling; Power system reliability; Power transformer insulation; Power transformers; Temperature dependence; Temperature distribution; Diffusion processes; Fault diagnosis; Finite element method; Oil insulations; Power transformer insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-1621-9
  • Electronic_ISBN
    978-1-4244-1622-6
  • Type

    conf

  • DOI
    10.1109/CMD.2008.4580328
  • Filename
    4580328