Title :
Correlation between UV-Vis spectral response and furan measurement of transformer oil
Author :
Lai, Sin P. ; Abu-Siada, A. ; Islam, Syed M. ; Lenco, Gary
Author_Institution :
Dept. of Electr. & Comput. Eng., Curtin Univ. of Technol., Perth, WA
fYear :
2008
fDate :
21-24 April 2008
Firstpage :
659
Lastpage :
662
Abstract :
Furans concentration presence in aged-transformer oil has been one of the key indicators of the solid dielectric deterioration. They are the by-products from the cellulose degradation of insulation paper caused by heat, oxidation and electrical stress. Nowadays, furans concentration is measured by high-performance liquid chromatography (HPLC) or gas chromatography-mass spectrometry (GC/MS) based on the standard of ASTM D 5837. Both analysis methods provide accurate and reliable results in detecting the concentration of furan derivatives (2-acetyl furan, 2-furfural, 5-methyl-2-furfural, 5-hydroxymethyl 2-furfural, and 2-furfurylalcohol). However, these two methods need very expensive equipments and take long time to get the results in addition an expert person is required to perform the analysis. This paper presents a novel approach of the correlation between the ultraviolet-to-visible (UV-Vis) spectral response that can be measured in a instantly with a relatively cheap equipment and does not need an expert person and furan measurement of transformer oil. Results show that there is a good correlation between UV-Vis spectral response and Furans concentration of transformer oil and an accurate method that can determine the furan concentration by measuring the UV-Vis spectral response can be developed.
Keywords :
chromatography; mass spectroscopy; transformer oil; 2-acetyl furan; 2-furfurylalcohol; 5-hydroxymethyl 2-furfural; 5-methyl-2-furfural; UV-Vis spectral response; cellulose degradation; furan concentration; furan measurement; gas chromatography; high-performance liquid chromatography; mass spectrometry; solid dielectric deterioration; transformer oil; Degradation; Dielectric measurements; Dielectrics and electrical insulation; Oil insulation; Oxidation; Petroleum; Power transformer insulation; Resistance heating; Solids; Stress; Furans; Furfural; Gas Chromatography-Mass Spectrometry; Spectral Analysis; Transformer Oil; Ultraviolet Spectroscopy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-1621-9
Electronic_ISBN :
978-1-4244-1622-6
Type :
conf
DOI :
10.1109/CMD.2008.4580372
Filename :
4580372
Link To Document :
بازگشت