Title : 
Investigation of return voltage measurement for the assessment of power transformers
         
        
            Author : 
Zhang, Rui-gang ; Dong, Ming ; Zhang, Guan-Jun ; Yan, Zhang
         
        
            Author_Institution : 
Sch. of Electr. Eng., Xi´´an Jiaotong Univ., Xian
         
        
        
        
        
        
            Abstract : 
Moisture and ageing in power transformer strongly influence the dielectric properties of oil/paper insulation system. Moisture measurement in oil sample generally gives inconclusive information since oil/paper moisture equilibrium is temperature dependent and takes a long time to be in equilibrium. Direct moisture measurement of paper sample is not practicable for in-service transformers. The measurement and evaluation of the ldquodielectric responserdquo is one possible way of diagnosing a transformer insulation condition. In a recent research project, return voltage measurement has been used for assessing the condition of oil/paper insulation. The return voltage measurement analysis is a non-destructive dielectric testing method for determining the ageing process and moisture content of insulation materials in a transformer. This paper presents a description of return voltage measurement principle explanation and the influencing factors. Furthermore, by analyzing large number of field test data, the criterion of oil-paper ageing is also presented.
         
        
            Keywords : 
nondestructive testing; paper; power transformer insulation; transformer oil; voltage measurement; dielectric response; in-service transformers; moisture measurement; nondestructive dielectric testing method; oil insulation system; paper insulation system; power transformers; return voltage measurement; Aging; Dielectric measurements; Dielectrics and electrical insulation; Moisture measurement; Oil insulation; Petroleum; Power transformer insulation; Power transformers; Temperature dependence; Voltage measurement; Depolarization currents; Dielectric response; Return voltage measurement; Simulation;
         
        
        
        
            Conference_Titel : 
Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
         
        
            Conference_Location : 
Beijing
         
        
            Print_ISBN : 
978-1-4244-1621-9
         
        
            Electronic_ISBN : 
978-1-4244-1622-6
         
        
        
            DOI : 
10.1109/CMD.2008.4580429