Title :
Epoxy, Urethane, Silicone; choice of encapsulant for high reliability magnetic components
Author :
Arris, Howard W. ; Trujillo, Manny O. ; Sanchez, Robert O.
Author_Institution :
Sandia Nat. Labs., xx, USA
Abstract :
Sandia National Laboratories has been encapsulating magnetic components for over 40 years. The reliability of magnetic component assemblies that must withstand a variety of environments and then function correctly is dependent on the use of appropriate encapsulating formulations. Specially developed formulations are critical and enable us to provide high reliability magnetic components. This paper discuss epoxy, urethane, and silicone formulations for several of our magnetic components.
Keywords :
encapsulation; epoxy insulation; magnetic cores; power transformers; reliability; silicone insulation; epoxy formulations; magnetic component encapsulation; magnetic component reliability; power transformers; silicone formulations; urethane formulations; Electric shock; Encapsulation; Ferrites; Laboratories; Magnetic materials; Magnetic separation; Power transformers; Testing; Thermal stresses; Vibrations;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Technology Conference, 2003. Proceedings
Print_ISBN :
0-7803-7935-7
DOI :
10.1109/EICEMC.2003.1247888