Title :
Introduction of a severity voltage parameter in a PD testing procedure of enamelled wire twisted pairs
Author :
Guastavino, F. ; Coletti, G. ; Dardano, A. ; Torello, E.
Author_Institution :
Dept. of Electr. Eng., Genova Univ., Italy
Abstract :
In this work a model for lifetime prediction, based on a severity voltage parameter which depends on the PD stress, is obtained. Then it is applied in the frame of a campaign of aging tests on twisted pairs specimens. The tests output evidenced that when distorted or high frequency voltages up to 550 Hz are applied to the samples, under PD activity, the present model is more meaningful taking in account the actual waveform shape, then all the points where PD inception can occur, not simply the voltage´s maximum amplitude.
Keywords :
ageing; insulated wires; insulation testing; partial discharges; 550 Hz; aging tests; enamelled wire twisted pairs; lifetime prediction; partial discharge stress; partial discharge testing; twisted pairs specimens; voltage parameter; voltages maximum amplitude; waveform shape; Aging; Circuit testing; Frequency; Insulation; Partial discharges; Power system harmonics; Signal generators; Stress; Voltage; Wire;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Technology Conference, 2003. Proceedings
Print_ISBN :
0-7803-7935-7
DOI :
10.1109/EICEMC.2003.1247911