• DocumentCode
    2322370
  • Title

    Introduction of a severity voltage parameter in a PD testing procedure of enamelled wire twisted pairs

  • Author

    Guastavino, F. ; Coletti, G. ; Dardano, A. ; Torello, E.

  • Author_Institution
    Dept. of Electr. Eng., Genova Univ., Italy
  • fYear
    2003
  • fDate
    23-25 Sept. 2003
  • Firstpage
    359
  • Lastpage
    362
  • Abstract
    In this work a model for lifetime prediction, based on a severity voltage parameter which depends on the PD stress, is obtained. Then it is applied in the frame of a campaign of aging tests on twisted pairs specimens. The tests output evidenced that when distorted or high frequency voltages up to 550 Hz are applied to the samples, under PD activity, the present model is more meaningful taking in account the actual waveform shape, then all the points where PD inception can occur, not simply the voltage´s maximum amplitude.
  • Keywords
    ageing; insulated wires; insulation testing; partial discharges; 550 Hz; aging tests; enamelled wire twisted pairs; lifetime prediction; partial discharge stress; partial discharge testing; twisted pairs specimens; voltage parameter; voltages maximum amplitude; waveform shape; Aging; Circuit testing; Frequency; Insulation; Partial discharges; Power system harmonics; Signal generators; Stress; Voltage; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Technology Conference, 2003. Proceedings
  • ISSN
    0362-2479
  • Print_ISBN
    0-7803-7935-7
  • Type

    conf

  • DOI
    10.1109/EICEMC.2003.1247911
  • Filename
    1247911