Abstract :
This paper deals with the maintenance of the generator. Three primary tools such as monitoring, inspection, testing are used to assess the generator condition. Use of all available knowledge on a specific generator can minimize the maintenance costs required to maintain a high level of reliability on the generator. To accomplish this goal, good operation and maintenance records are important, as well as attention to all available monitoring information, performance of a high caliber inspection, and judicious use of a selected set of appropriate off-line tests.
Keywords :
AC generators; condition monitoring; inspection; machine testing; maintenance engineering; reliability; generator condition; generator maintenance; generator reliability; generator testing; high caliber inspection; maintenance cost; Inspection; Instruments; Monitoring; Partial discharges; Personnel; Probes; Stator windings; Temperature sensors; Testing; Vibration measurement;