DocumentCode :
2323249
Title :
Optimum core dimensions of transformer for switching power supplies
Author :
Katane, T. ; Nohgi, H. ; Sakaki, Y.
Author_Institution :
Fac. of Eng., Chiba Univ., Japan
fYear :
1994
fDate :
20-25 Jun 1994
Firstpage :
24
Abstract :
A new method for designing high frequency power transformers economically is proposed. In contrast to the conventional method, only the temperature rise is given at first and the core shape and winding result from the method. In this study a new design factor, which brings about an optimum transformer, is also introduced
Keywords :
high-frequency transformers; losses; magnetic cores; power supplies to apparatus; switched mode power supplies; switching circuits; transformer cores; core shape; high frequency power transformers; optimum core dimensions; switching power supplies; temperature rise; transformer; winding; Copper; Core loss; Costs; Design methodology; Frequency; Power generation economics; Power supplies; Power transformers; Shape; Switching frequency; Temperature; Transformer cores;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, PESC '94 Record., 25th Annual IEEE
Conference_Location :
Taipei
Print_ISBN :
0-7803-1859-5
Type :
conf
DOI :
10.1109/PESC.1994.349754
Filename :
349754
Link To Document :