Title :
Noninvasive diagnosis of carbon monoxide poisoning using Extended Modified Lambert Beer Model
Author :
Huong, Audrey ; Ngu, Xavier
Author_Institution :
Fac. of Electr. & Electron. Eng., Univ. Tun Hussein Onn Malaysia, Batu Pahat, Malaysia
Abstract :
We aim to demonstrate the feasibility of using Extended Modified Lambert Beer model (EMLB) to detect differences in percent mean blood oxyhemoglobin (SmO2) and carboxyhemoglobin (SmCO) saturations between smoking and nonsmoking populations. The value of these parameters is given by those that produced the closest agreement between the EMLB and the measured data optimized using the developed fitting routine. This fitting algorithm used extinction coefficients of light absorbing hemoglobin species in the wavelength range of 520-600 nm as the background information. The reflectance spectroscopy measurement on left thumb of five smokers and four nonsmokers at rest condition revealed percent SmO2 and SmCO with mean value of 81.9 ± 8.8% and 16.2 ± 4.8%, respectively, for smoking population. Meanwhile a higher mean SmO2 of 86.5 ± 1.6% and lower mean SmCO of 11.7 ± 1.6% are observed for nonsmoking individuals. These values are compared to that reported in the literature. This study concluded that the proposed model and fitting strategy is able to detect differences in percent blood saturations of smoking and nonsmoking volunteers, hence potentially be used to clinically detect carbon monoxide poisoning in men.
Keywords :
biochemistry; biotransport; blood; carbon compounds; cellular biophysics; health hazards; patient care; patient diagnosis; proteins; spectrochemical analysis; spectrophotometers; toxicology; CO; EMLB model; O2; SmCO saturation; SmO2 saturation; carbon monoxide poisoning detection; carboxyhemoglobin; clinical CO poisoning detection; developed fitting routine; extended modified Lambert beer model; extinction coefficients; fitting routine algorithm; light absorbing hemoglobin species; measured data optimization; noninvasive CO poisoning diagnosis; nonsmoker left thumb; nonsmoking populations; nonsmoking volunteer blood saturation; parameter values; percent mean blood oxyhemoglobin; reflectance spectroscopy measurement; smoking volunteer blood saturations; wavelength 520 nm to 600 nm; Absorption; Attenuation; Blood; Fitting; Skin; Sociology; Thumb; Extended Modified Lambert Beer model; blood carboxyhemoglobin saturation; blood oxyhemoglobin saturation; carbon monoxide poisoning; spectroscopy;
Conference_Titel :
Electronic Design (ICED), 2014 2nd International Conference on
Conference_Location :
Penang
DOI :
10.1109/ICED.2014.7015811