• DocumentCode
    2327344
  • Title

    Performance characteristics of coal-fired MHD generator/line-commutated inverter system of commercial scale

  • Author

    Iwashita, T. ; Inui, Yoshitaka ; Matsuo, T. ; Ishikawa, M. ; Umoto, J.

  • Author_Institution
    Dept. of Electr. Eng., Kyoto Univ., Japan
  • Volume
    2
  • fYear
    1998
  • fDate
    18-21 Aug 1998
  • Firstpage
    1183
  • Abstract
    Fault analyses are carried out for an interconnecting system of a subsonic diagonal type MHD generator and an AC power system. When lines faults, such as single-line ground faults, occur in the transmission line, inverters are short-circuited and load currents of the MHD generator increase significantly. Some control of the firing angle is required to recover normal inverter operation. The interconnecting system can be restored to the nominal condition after this recovery of normal inverter operation
  • Keywords
    DC-AC power convertors; coal; combustion; commutation; invertors; magnetohydrodynamic convertors; magnetohydrodynamic power plants; power system interconnection; power transmission faults; power transmission lines; AC power system; coal-fired MHD generator; fault analyses; invertor firing angle; line-commutated inverter system; performance characteristics; single-line ground faults; subsonic diagonal type MHD generator; transmission line; Circuit faults; Integrated circuit interconnections; Inverters; Magnetohydrodynamic power generation; Power generation; Power system analysis computing; Power system faults; Power system interconnection; Power system restoration; Power transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power System Technology, 1998. Proceedings. POWERCON '98. 1998 International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    0-7803-4754-4
  • Type

    conf

  • DOI
    10.1109/ICPST.1998.729272
  • Filename
    729272