DocumentCode :
2328575
Title :
Time requirements of hard- versus soft-copy interpretation of SICU computed radiographic images
Author :
Boushka, W.M. ; Perez, G. ; Chacko, A.K.
Author_Institution :
Brooke Army Med. Center, USA
fYear :
1995
fDate :
20-24 Aug 1995
Firstpage :
202
Lastpage :
208
Abstract :
The Brooke Army Medical Center PACS was used to produce paired hard copy and soft copy interpretations of computed radiography images of SICU patients for eight days. There was no statistical difference in the time spent setting up and reading hard copy vs. the setup and reading time for soft copy interpretation. The time required for the radiologists to display and read the soft copy studies was 33% longer than the time required to view and interpret the same hard copy studies which had been previously placed on a film rotator
Keywords :
PACS; diagnostic radiography; human factors; Brooke Army Medical Center; PACS; SICU patients; computed radiography images; hard copy; soft copy; Biomedical imaging; Computer aided manufacturing; Computer displays; Diagnostic radiography; Image storage; Medical diagnostic imaging; Military computing; Optical arrays; Optical computing; Picture archiving and communication systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image Management and Communications, 1995., Proceedings of the Fourth International Conference on
Conference_Location :
Oahu Island, HI
Print_ISBN :
0-8186-7560-8
Type :
conf
DOI :
10.1109/IMAC.1995.532585
Filename :
532585
Link To Document :
بازگشت