DocumentCode :
2330474
Title :
Cost reduction and control system improvement in Electrical Arc Furnace using DVR
Author :
Toodeji, H. ; Fathi, S.H.
Author_Institution :
Dept. of Electr. Eng., Amirkabir Univ. of Technol. (Tehran Polytech.), Tehran
fYear :
2009
fDate :
25-27 May 2009
Firstpage :
211
Lastpage :
215
Abstract :
Today, electrical arc furnaces (EAF) are used widely to produce steel and its alloys. This kind of furnace has a noticeable superiority over the other types of furnaces because of its steel production procedure. Nevertheless EAF emerges as a large, nonlinear and time-varying load in the power system which causes many power quality problems such as current unbalance, harmonic pollution and poor power factor. On the other hand, especial equipments such as the furnace transformer with the endurance of durable short circuit currents and a tap changer with many steps must be used. Also a sluggish mechanical control system is used to move the electrodes. These equipments increase the overall cost of EAF and give it slow response. In order to solve some of the aforementioned problems, a dynamic voltage restorer (DVR) can be installed near the EAF. The DVR is capable of improving power quality, reducing the overall cost and enhancing the system controllability by elimination of the tap changer and modification in the electrode movement controller. An appropriate control system is introduced to manage this DVR and its effectiveness is testified by computer simulation using MATLAB/simulink software.
Keywords :
arc furnaces; power supply quality; Matlab-Simulink software; control system improvement; cost reduction; current unbalance; dynamic voltage restorer; electrical arc furnace; electrode movement controller; furnace transformer; harmonic pollution; mechanical control system; power factor; power quality improvement; power system; short circuit currents; steel production procedure; tap changer; Control systems; Costs; Electrodes; Furnaces; Iron alloys; Power quality; Power system harmonics; Production; Steel; Time varying systems; Dynamic Voltage Restorer (DVR); Electrical Arc Furnace (EAF); Furnace transformer; Power Quality;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics and Applications, 2009. ICIEA 2009. 4th IEEE Conference on
Conference_Location :
Xi´an
Print_ISBN :
978-1-4244-2799-4
Electronic_ISBN :
978-1-4244-2800-7
Type :
conf
DOI :
10.1109/ICIEA.2009.5138198
Filename :
5138198
Link To Document :
بازگشت