• DocumentCode
    2334110
  • Title

    The Daresbury personnel safety system

  • Author

    Poole, D.E. ; Ring, T.

  • Author_Institution
    SERC Daresbury Lab., Warrington, UK
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    1931
  • Abstract
    The personnel safety system designed for the Synchrotron Radiation Source (SRS) at Daresbury is a unified system covering the three accelerators of the source itself, the beamlines, and the experimental stations. The system has also been applied to the experimental areas of the Nuclear Structure Facility, and is therefore established as a site standard. A dual guardline interlock module forms a building block for a relay-based interlock system completely independent of the machine control system, although comprehensive monitoring of the system status via the control system computer is a feature. An outline of the design criteria adopted for the system is presented together with a more detailed description of the philosophy of the guardline logic and the way this is implemented in a standard modular form. The emphasis is on the design features of a modern microprocessor-based variant of the original SRS system. Experience with the original system during buildup and operation of the SRS facility is described
  • Keywords
    nuclear electronics; safety; storage rings; Daresbury; Synchrotron Radiation Source; control system computer; dual guardline interlock module; personnel safety system; relay-based interlock system; Control systems; Linear particle accelerator; Machine control; Personnel; Protection; Safety; Storage rings; Structural beams; System testing; X-rays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.72973
  • Filename
    72973